<?xml version="1.0" encoding="UTF-8"?>
<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns="http://purl.org/rss/1.0/" xmlns:sy="http://purl.org/rss/1.0/modules/syndication/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/">
  <channel>
    <title>DSpace collection: 期刊論文</title>
    <link>http://140.112.115.32:8080/ir/handle/987654321/1116</link>
    <description />
    <items>
      <rdf:Seq>
        <rdf:li resource="http://140.112.115.32:8080/ir/handle/987654321/2864" />
        <rdf:li resource="http://140.112.115.32:8080/ir/handle/987654321/2860" />
        <rdf:li resource="http://140.112.115.32:8080/ir/handle/987654321/2681" />
        <rdf:li resource="http://140.112.115.32:8080/ir/handle/987654321/2679" />
      </rdf:Seq>
    </items>
  </channel>
  <textInput>
    <title>The collection's search engine</title>
    <description>Search the Channel</description>
    <name>s</name>
    <link>http://140.112.115.32:8080/ir/simple-search</link>
  </textInput>
  <item rdf:about="http://140.112.115.32:8080/ir/handle/987654321/2864">
    <title>Reference equivalent threshold sound pressure levels for Apple Earpods</title>
    <link>http://140.112.115.32:8080/ir/handle/987654321/2864</link>
    <description>title: Reference equivalent threshold sound pressure levels for Apple Earpods abstract: Reference equivalent threshold sound pressure levels (RETSPLs) are used when calibrating audiometric equipment to a hearing threshold level of zero at various frequencies. To the best of the authors' knowledge, the RETSPLs for Apple EarPods (MB770G) have not been reported, and so this study aimed to measure them. The hearing thresholds of 36 normal-hearing subjects (72 ears) were measured at 250, 500, 1000, 2000, 4000, and 8000 Hz, with the measurements being performed twice in 33 subjects (66 ears) for evaluating the test–retest reliability. This study provides Apple EarPod RETSPLs and shows significant Pearson's correlations (p &lt; 0.001) with no significant Wilcoxon signed-rank test differences (p &gt; 0.01), which confirm the test reliability.
&lt;br&gt;</description>
  </item>
  <item rdf:about="http://140.112.115.32:8080/ir/handle/987654321/2860">
    <title>Efficacy of a Smartphone Hearing Aid Simulator</title>
    <link>http://140.112.115.32:8080/ir/handle/987654321/2860</link>
    <description>title: Efficacy of a Smartphone Hearing Aid Simulator abstract: Purpose&#xD;
Almost all smartphone-based personal sound amplification applications (PSAPs) do not provide amplification specifications as well as medical hearing aid (HA) products. Therefore, the main purpose of this study is to develop an HA-simulator and investigate the possible fitting range of this smartphone-based PSAP app equipped with a commercial headset, and to evaluate whether the aided outcome provides reasonable benefits for individuals with hearing loss by analyzing the Speechmap and speech intelligibility index (SII).&#xD;
Methods&#xD;
An HA-simulator with a four-channel compression structure was developed and evaluated using a smartphone equipped with Apple EarPods. Measurement methods specified by the ANSI S3.22 were used to evaluate the electroacoustic performance of the proposed system. The Speechmap method and SII were used to check if the amplified speech for five different hearing loss configurations. These ANSI S3.22 and Speechmap measurement results were then compared with a digital HA under the same test conditions.&#xD;
Results&#xD;
The results demonstrated that the proposed HA-simulator system provided an adequate output sound level for patients with mild-to-moderate hearing loss and a tolerable group delay for the user while providing an electroacoustic performance comparable to that of a digital HA based on ANSI S3.22 test criteria. The amplified speech signals presented by Speechmap and the corresponding SII values indicated that the proposed HA-simulator provided benefits comparable to those of medical HA.&#xD;
Conclusions&#xD;
These results indicate that a smartphone-based HA simulator could provide suitable performance to that of a medical HA, and it potentially aid individuals with hearing loss.
&lt;br&gt;</description>
  </item>
  <item rdf:about="http://140.112.115.32:8080/ir/handle/987654321/2681">
    <title>聽神經病變兒童的聽力學管理</title>
    <link>http://140.112.115.32:8080/ir/handle/987654321/2681</link>
    <description>title: 聽神經病變兒童的聽力學管理</description>
  </item>
  <item rdf:about="http://140.112.115.32:8080/ir/handle/987654321/2679">
    <title>鼻竇內視鏡手術出血量相關因子的分析及探討</title>
    <link>http://140.112.115.32:8080/ir/handle/987654321/2679</link>
    <description>title: 鼻竇內視鏡手術出血量相關因子的分析及探討</description>
  </item>
</rdf:RDF>

