馬偕醫學院機構典藏(Mackay Medical College Institutional Repository):Item 987654321/2244
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 1592/1691
Visitors : 1399274      Online Users : 189
RC Version 5.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Adv. Search
LoginUploadHelpAboutAdminister

Please use this identifier to cite or link to this item: http://140.112.115.32:8080/ir/handle/987654321/2244

Title: Airway changes in children with mucopolysaccharidoses: CT evaluation
Authors: Shin-Lin Shih;Yann-Jinn Lee;Shuan-Pei Lin;Chin-Yin Sheu;Johan G. Blickman
Contributors: 生醫所
Date: 2002-01-01
Issue Date: 2015-12-08 12:19:57 (UTC+8)
Abstract: Objective: To assess the CT findings of the airway in children with mucopolysaccharidoses (MPS).

Material and Methods: The study included 13 patients (9 boys, 4 girls; age range 2-17 years; mean age 9.2 years) with MPS: 6 with Hunter syndrome, 3 with Maroteaux-Lamy syndrome, 2 with Sanfilippo syndrome, 1 with Hurler/Scheie syndrome and 1 with Morquio syndrome. CT of the airways was done in the axial section with 3-mm collimation from the oropharynx at the level of C3 to the base of the lung. The shape of the vocal cords and trachea at the level of T1 was evaluated. The tracheal surface area (TSA) at the level of T1 was measured both in patients and in age-matched subjects.

Results: CT showed an abnormality of the vocal cords in 7 of the 13 patients. Six patients had an abnormal shape and 7 had an inhomogenous density. The abnormalities included elliptical (5 of 6) and star-shaped (1 of 6) cords. Eight of 13 tracheas were also abnormal, either U-shaped (6 of 8) or worm-shaped (2 of 8). The TSA was significantly smaller in patients (79.6±28.9 mm2) than in control subjects (138.1±50.1 mm2). The TSA of those ≤⃒9 years was 61.4±15.2 mm2 as compared with 99.9±23.5 mm2 for the control group. The TSA of patients ≥11 years was 107.1±25.3 mm2 as compared with 187.6±32.0 mm2 for the control group.

Conclusion: Significant changes in the shape of the vocal cords and trachea in patients with MPS were found. The most common abnormal configuration of trachea was the U-shape. The TSA was smaller in patients with MPS than in controls. The airway changes may be due to abnormal submucosal storage of substances such as keratan or dermatan sulfate.
Relation: Acta Radiologica, 43(1), 40-43. doi:10.1080/028418502127347628
https://doi.org/10.1080/028418502127347628
Appears in Collections:[Institute of Biomedical Sciences] Journal papers

Files in This Item:

File SizeFormat
index.html0KbHTML182View/Open


All items in MMCIR are protected by copyright, with all rights reserved.

 


DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback