摘要: Reference equivalent threshold sound pressure levels (RETSPLs) are used when calibrating audiometric equipment to a hearing threshold level of zero at various frequencies. To the best of the authors' knowledge, the RETSPLs for Apple EarPods (MB770G) have not been reported, and so this study aimed to measure them. The hearing thresholds of 36 normal-hearing subjects (72 ears) were measured at 250, 500, 1000, 2000, 4000, and 8000 Hz, with the measurements being performed twice in 33 subjects (66 ears) for evaluating the test–retest reliability. This study provides Apple EarPod RETSPLs and shows significant Pearson's correlations (p < 0.001) with no significant Wilcoxon signed-rank test differences (p > 0.01), which confirm the test reliability.
關聯: The Journal of the Acoustical Society of America Express Letters, 141(2), EL115-EL119. https://doi.org/10.1121/1.4976110
显示于类别:[高齡福祉科技研究所] 期刊論文
[聽力暨語言治療學系] 期刊論文

文件中的档案:

档案 大小格式浏览次数
index.html0KbHTML9检视/开启


在MMUIR中所有的数据项都受到原著作权保护.

 


DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈